All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Quantify analyte concentrations in prepared samples by means of Flame Atomic Absorption Spectroscopy |
SAQA US ID | UNIT STANDARD TITLE | |||
256628 | Quantify analyte concentrations in prepared samples by means of Flame Atomic Absorption Spectroscopy | |||
ORIGINATOR | ||||
SGB Mining and Minerals | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 06 - Manufacturing, Engineering and Technology | Fabrication and Extraction | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 4 | NQF Level 04 | 15 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2018-07-01 | 2023-06-30 | SAQA 06120/18 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2024-06-30 | 2027-06-30 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard replaces: |
US ID | Unit Standard Title | Pre-2009 NQF Level | NQF Level | Credits | Replacement Status |
9630 | Quantify analyte concentrations in prepared samples by means of Flame Atomic Absorption Spectroscopy | Level 3 | NQF Level 03 | 15 |
PURPOSE OF THE UNIT STANDARD |
This unit standard will be useful for people responsible for analysing analyte samples by means of Flame Atomic Absorption Spectroscopy.
This unit standard is intended to promote general skills and knowledge of analyzing samples by means of Flame Atomic Absorption Spectroscopy. Learners credited with this unit standard are able to: |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
It is assumed that learners are already competent in terms of:
|
UNIT STANDARD RANGE |
N/A |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Demonstrate knowledge and skills relating to occupational health, safety and environment. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Occupational hazards and risks pertaining to the flame atomic absorption spectroscopy determination are identified and explained with reference to occupational health and safety and environmental impact. |
ASSESSMENT CRITERION RANGE |
Occupational hazards and risks must include:
|
ASSESSMENT CRITERION 2 |
The appropriate preventive measures to deal with occupational hazards and risks are described in accordance with specified requirements. |
ASSESSMENT CRITERION 3 |
The required fit for purpose personal protective equipment is used in accordance with legal and operational requirements. |
ASSESSMENT CRITERION 4 |
Work is conducted to meet occupational health, safety and environmental standards. |
ASSESSMENT CRITERION RANGE |
Occupational health, safety and environmental issues must include:
|
ASSESSMENT CRITERION 5 |
The consequences of non-compliance with specified requirements are explained with respect to occupational personal and occupational health and safety and impact on the environment. |
SPECIFIC OUTCOME 2 |
Demonstrate knowledge relating to Flame Atomic Absorption Spectroscopy. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The basic principle of atomic absorption is explained with reference to this analytical technique. |
ASSESSMENT CRITERION 2 |
The principal components of the Flame Atomic Absorption Spectrophotometer are correctly identified and their primary functions are briefly described in accordance with operational requirements. |
ASSESSMENT CRITERION RANGE |
Identification must include:
|
ASSESSMENT CRITERION 3 |
The impacts of various parameters are explained with reference to obtaining optimal absorbance in accordance with operational requirements. |
ASSESSMENT CRITERION RANGE |
Explanation must include:
|
ASSESSMENT CRITERION 4 |
The relevance of releasing agents, matrix matching and ionization suppressants are explained with reference to preparation of standard and sample solutions. |
ASSESSMENT CRITERION 5 |
The purpose of the determination is explained in terms of customer requirements. |
SPECIFIC OUTCOME 3 |
Determine analyte concentration in prepared samples. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The calibration standards are prepared and are appropriate with respect to sample matrix and concentration range for the particular sample solutions. |
ASSESSMENT CRITERION 2 |
The Flame Atomic Absorption Spectrophotometer is optimized and calibrated in accordance with operational requirements. |
ASSESSMENT CRITERION 3 |
The prepared samples are identified, verified and the analyte concentration is measured in accordance with operational requirements and quality control procedures. |
ASSESSMENT CRITERION RANGE |
Must include analyses using the following flames:
|
ASSESSMENT CRITERION 4 |
Data is recorded, analyte concentrations calculated and results reported in accordance with operational requirements within agreed turnaround times. |
ASSESSMENT CRITERION 5 |
Equipment is maintained in accordance with specified requirements. |
ASSESSMENT CRITERION RANGE |
Equipment must include:
|
SPECIFIC OUTCOME 4 |
Explain or deal with problems relating to Flame Atomic Absorption Spectroscopy. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Common problems and their effect on the process are explained and/or dealt with in accordance with operational requirements. |
ASSESSMENT CRITERION RANGE |
Range must include those for:
|
ASSESSMENT CRITERION 2 |
Appropriate preventive or corrective actions are described in accordance with operational requirements. |
ASSESSMENT CRITERION 3 |
The work is conducted in a manner that ensures continuity, and supports a smooth flow throughout the process in accordance with operational requirements. |
ASSESSMENT CRITERION 4 |
The effect of non-compliance is explained in terms of production, quality, costs and lost time and turnaround time for analytical results. |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
Embedded knowledge is addressed in an integrated way in the unit standard.
Knowledge relating to quantifying analyte concentrations in prepared samples by means of flame atomic absorption spectrometry: Critical factors and functions relating to the process: Processes and events: Causes and effects (Safety and Health): Procedures and techniques: Regulations, legislation, agreements, policies and standards: |
UNIT STANDARD DEVELOPMENTAL OUTCOME |
N/A |
UNIT STANDARD LINKAGES |
N/A |
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO WORKING |
The learner's ability to work to high levels of accuracy and inconsistency will contribute to the overall performance of the laboratory team. |
UNIT STANDARD CCFO ORGANISING |
The learner's ability to follow work procedures closely, adhering meticulously to relevant procedures when quantifying analyte concentrations in prepared samples. |
UNIT STANDARD CCFO COLLECTING |
The learner's ability to keep accurate records and make accurate entries into the relevant log sheets. |
UNIT STANDARD CCFO SCIENCE |
The learner's ability to use and interact with technologically advanced procedures and equipment in a modern laboratory environment when quantifying analyte concentrations in prepared samples by means of flam atomic absorption spectometry. |
UNIT STANDARD CCFO DEMONSTRATING |
The learner is aware that in the mining (refining) industry various systems are dependent on each other, and accepts responsibility in that regard. |
UNIT STANDARD ASSESSOR CRITERIA |
N/A |
REREGISTRATION HISTORY |
As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. |
UNIT STANDARD NOTES |
This unit standard replaces unit standard 9630, "Quantify analyte concentrations in prepared samples by means of Flame Atomic Absorption Spectroscopy", Level 3, 15 Credits.
Terminology: Specified Requirements: Specified requirements include legal and site-specific requirements and are contained in one or more of the following documents: Legal: Site Specific: |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Elective | 64950 | Further Education and Training Certificate: Laboratory Analysis | Level 4 | NQF Level 04 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | As per Learning Programmes recorded against this Qual |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
NONE |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |