All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Perform a sink-float analysis |
SAQA US ID | UNIT STANDARD TITLE | |||
256625 | Perform a sink-float analysis | |||
ORIGINATOR | ||||
SGB Mining and Minerals | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 06 - Manufacturing, Engineering and Technology | Fabrication and Extraction | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 3 | NQF Level 03 | 5 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2018-07-01 | 2023-06-30 | SAQA 06120/18 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2024-06-30 | 2027-06-30 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard replaces: |
US ID | Unit Standard Title | Pre-2009 NQF Level | NQF Level | Credits | Replacement Status |
9741 | Perform a sink-float analysis | Level 3 | NQF Level 03 | 5 |
PURPOSE OF THE UNIT STANDARD |
This unit standard will be useful for people who are required to perform the separation of ore on the basis of density.
This unit standard is intended to promote general skills and knowledge of performing the separation of ore on the basis of density in the mining and minerals sector in order to ensure knowledgeable and informed workers. People credited with this unit standard are able to: |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
It is assumed that learners are already competent in:
|
UNIT STANDARD RANGE |
N/A |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Demonstrate knowledge relating to the sink-float process. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Hazards and risks pertaining to the sampling process are identified and explained in terms of team safety, health and environmental issues. |
ASSESSMENT CRITERION 2 |
The appropriate preventative measures are described in accordance with specified requirements. |
ASSESSMENT CRITERION 3 |
The principal components needed for the sink-float process are identified and their functions explained in accordance with operational requirements. |
ASSESSMENT CRITERION 4 |
The reasons for performing a sink-float determination are explained in terms of process control, analysis required and operational requirements. |
ASSESSMENT CRITERION 5 |
Common problems are explained in terms of their effect on the process and appropriate preventative or corrective actions described in accordance with operational requirements. |
ASSESSMENT CRITERION 6 |
The consequences of non-compliance with specified requirements are explained with respect to personal and team health and safety, impact on the environment, production, costs and lost time. |
SPECIFIC OUTCOME 2 |
Prepare for and perform the sink-float process. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Personal protective and safety equipment is examined, verified and used in accordance with specified requirements. |
ASSESSMENT CRITERION 2 |
Equipment is examined and verified in accordance with operational requirements. |
ASSESSMENT CRITERION RANGE |
Equipment must include:
|
ASSESSMENT CRITERION 3 |
The samples and the appropriate method are verified in accordance with operational requirements. |
ASSESSMENT CRITERION 4 |
Chemicals required are examined, verified and prepared according to legal and operational requirements. |
ASSESSMENT CRITERION 5 |
The work is conducted to meet sampling, security, safety, health and environmental standards in accordance with legal and operational requirements. |
ASSESSMENT CRITERION RANGE |
Safety, health and environmental issues must include:
|
ASSESSMENT CRITERION 6 |
A sink-float determination is conducted in accordance with operational requirements. |
ASSESSMENT CRITERION 7 |
Problems encountered during the process are dealt with in accordance with operational requirements. |
ASSESSMENT CRITERION 8 |
Data is processed and results calculated in accordance with legal and operational requirements. |
ASSESSMENT CRITERION 9 |
The sample is processed for further analysis in accordance with operational requirements. |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
Knowledge relating to performing a sink-float analysis:
Critical factors and functions relating to the process: Processes and events: Causes and effects (Safety and Health): Procedures and techniques: Regulations, legislation, agreements, policies and standards: |
UNIT STANDARD DEVELOPMENTAL OUTCOME |
N/A |
UNIT STANDARD LINKAGES |
N/A |
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO WORKING |
The learners ability to work to high levels of accuracy and inconsistency will contribute to the overall performance of the laboratory team. |
UNIT STANDARD CCFO ORGANISING |
The learner's ability to follow work procedures closely, adhering meticulously to relevant procedures when performing a silk-float analysis. |
UNIT STANDARD CCFO COLLECTING |
The learner's ability to keep accurate records and make accurate entries into the relevant log sheets. |
UNIT STANDARD CCFO SCIENCE |
The learner's ability to use and interact with technologically advanced procedures and equipment in a modern laboratory environment when performing a silk-float analysis. |
UNIT STANDARD CCFO DEMONSTRATING |
The learner is aware that in the mining (refining) industry various systems are dependent on each other, and accepts responsibility in that regard. |
UNIT STANDARD ASSESSOR CRITERIA |
N/A |
REREGISTRATION HISTORY |
As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. |
UNIT STANDARD NOTES |
This unit standard replaces unit standard 9741, "Perform a sink-float analysis", Level 3, 5 credits.
Terminology: Specified Requirements: Specified requirements include legal and site-specific requirements and are contained in one or more of the following documents: Legal: Site-Specific: |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Elective | 64949 | National Certificate: Laboratory Practice | Level 2 | NQF Level 02 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | As per Learning Programmes recorded against this Qual |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
NONE |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |