All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Operate an anaerobic digester |
SAQA US ID | UNIT STANDARD TITLE | |||
12047 | Operate an anaerobic digester | |||
ORIGINATOR | ||||
SGB Water Sector | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 12 - Physical Planning and Construction | Civil Engineering Construction | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 4 | NQF Level 04 | 7 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2005-02-09 | 2008-02-09 | SAQA 1058/05 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2009-02-09 | 2012-02-09 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard is replaced by: |
US ID | Unit Standard Title | Pre-2009 NQF Level | NQF Level | Credits | Replacement Status |
255985 | Operate an anaerobic wastewater sludge digester | Level 3 | NQF Level 03 | 7 |
PURPOSE OF THE UNIT STANDARD |
The qualifying learner achieving this unit standard in combination with context expertise standard(s) will be able to operate an anaerobic digester in accordance with legislation, guidelines and procedures. This competence will enable the learner to monitor and maintain the anaerobic digester and interpret laboratory analytical results related to the functioning of the digester. Achieving this unit standard will enhance the efficiency of the qualifying learner as part of a wastewater team and advance his/her own expertise and employability in wastewater. |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
Numeracy NQF level 2;
Apply personal safety practices NQF level 2. |
UNIT STANDARD RANGE |
Work policies and procedures:
Best operating procedures. Laboratory analytical results: pH, alkalinity, volatile acids, temperature, solids (organic and inorganic) Reports: Maintenance, faults, irregularities. Information: Flows, quality, sample readings, breakdowns, incidents material requisitions etc. |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Operate sludge pump in accordance with work policies and procedures |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Pumps are checked while in operation for correct functioning. |
ASSESSMENT CRITERION 2 |
2. Sludge is checked for correct flow rate and concentration. |
ASSESSMENT CRITERION 3 |
3. Valve positions are checked. |
SPECIFIC OUTCOME 2 |
Operate anaerobic digester in accordance with works procedures and legislation |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Inflow is monitored. |
ASSESSMENT CRITERION 2 |
2. Anaerobic digester is operated. |
ASSESSMENT CRITERION 3 |
3. Problems are identified and appropriate corrective action is explained. |
SPECIFIC OUTCOME 3 |
Monitor anaerobic digester |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Sludge is monitored and samples are withdrawn at appropriate times. |
ASSESSMENT CRITERION 2 |
2. Gas production is monitored. |
ASSESSMENT CRITERION 3 |
3. Condensation is monitored and drained from gas line when necessary. |
ASSESSMENT CRITERION 4 |
4. pH levels are monitored and high / low levels are recorded and appropriate corrective action is taken. |
ASSESSMENT CRITERION 5 |
5. Laboratory analytical results are interpreted accurately and corrective action is explained. |
SPECIFIC OUTCOME 4 |
Maintain anaerobic digester in accordance with work policies and procedures |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Visual inspection of structure is completed. |
ASSESSMENT CRITERION 2 |
2. Seal on digester is checked. |
ASSESSMENT CRITERION 3 |
3. Routine maintenance and structural damage is identified and reported. |
ASSESSMENT CRITERION 4 |
4. Fault reports are accurate and the importance of accuracy is explained. |
ASSESSMENT CRITERION 5 |
5. Safety procedures are explained and demonstrated. |
SPECIFIC OUTCOME 5 |
Complete designated tasks and reports in accordance with work policies and procedures |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Designated tasks are completed. |
ASSESSMENT CRITERION 2 |
2. Reports are accurate and complete and handed in to relevant person. |
ASSESSMENT CRITERION 3 |
3. Relevant information is communicated. |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
Learners should have a knowledge and understanding of:
|
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO IDENTIFYING |
Identify and solve problems in which responses display that responsible decisions using critical and creative thinking have been made.
Assessment criteria: |
UNIT STANDARD CCFO WORKING |
Work effectively with others as a member of a team, group, organisation, and community.
Assessment criteria: |
UNIT STANDARD CCFO ORGANISING |
Plan, organise and manage oneself and one`s activities responsibly and effectively.
Assessment criteria: |
UNIT STANDARD CCFO COLLECTING |
Collect, analyse, organise and critically evaluate information.
Assessment criteria: |
UNIT STANDARD CCFO COMMUNICATING |
Communicate effectively using visual, mathematical and/or language skills in the form of oral and/or written presentation.
Assessment criteria: |
UNIT STANDARD CCFO SCIENCE |
Use science and technology effectively and critically, showing responsibility towards the environment and health of others.
Assessment criteria: |
UNIT STANDARD CCFO DEMONSTRATING |
Demonstrate an understanding of the world as a set of related systems by recognising that problem-solving contexts do not exist in isolation.
Assessment criteria: |
UNIT STANDARD NOTES |
This unit standard has been replaced by unit standard 255985, which is "Operate an anaerobic wastewater sludge digester", Level 3, 7 credits.
Integrated assessment: When conducting assessments, assessors must ensure that they are familiar with the full text of the unit standards being assessed. Assessors must ensure that the assessment covers the specific outcomes, critical cross-field outcomes and essential embedded knowledge by developing assessment activities and tools, which are appropriate to the contexts in which the learners are working. These activities and tools may include self-assessment, peer assessment, formative and summative assessment. It may be more effective and efficient to assess a number of unit standards together in an integrated way, thus reducing the overall number of assessments and ensuring that commonalities that exist between a number of unit standards are captured in a way that makes sense for assessment. Assessment option: Learners could be assessed using the following methods: Oral or written questions Observation |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Core | 22672 | National Certificate: Wastewater Process Control | Level 4 | NQF Level 04 | Passed the End Date - Status was "Reregistered" |
2008-06-11 | Was EWSETA until Last Date for Achievement |
Elective | 22673 | National Certificate: Wastewater Process Operations | Level 2 | NQF Level 02 | Passed the End Date - Status was "Reregistered" |
2007-11-28 | Was EWSETA until Last Date for Achievement |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
NONE |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |