All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Operate water treatment systems used in air-conditioning and refrigeration installations |
SAQA US ID | UNIT STANDARD TITLE | |||
116706 | Operate water treatment systems used in air-conditioning and refrigeration installations | |||
ORIGINATOR | ||||
SGB Air-conditioning Refrigeration and Ventilation | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 06 - Manufacturing, Engineering and Technology | Manufacturing and Assembly | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 3 | NQF Level 03 | 3 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2018-07-01 | 2023-06-30 | SAQA 06120/18 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2024-06-30 | 2027-06-30 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard replaces: |
US ID | Unit Standard Title | Pre-2009 NQF Level | NQF Level | Credits | Replacement Status |
13378 | Operate water treatment systems used in air-conditioning and refrigeration installations | Level 3 | NQF Level 03 | 3 |
PURPOSE OF THE UNIT STANDARD |
Operate water treatment systems used in refrigeration and air-conditioning installations without injury to persons or damage to equipment or environment. |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
UNIT STANDARD RANGE |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Explain the reasons for water treatment. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The factors that reduce heat exchange are listed and explained. |
ASSESSMENT CRITERION 2 |
The effects of heating the water on the heat exchange are listed and discussed. |
SPECIFIC OUTCOME 2 |
Explain the effect of non-treatment of the water. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The effects non-treatment has on plant operation and life are listed and discussed. |
SPECIFIC OUTCOME 3 |
Obtain water samples from each of the circuits. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The need for taking precautions against samples becoming contaminated by external contaminants is explained. |
ASSESSMENT CRITERION 2 |
Samples being taken for analysis are not contaminated by or during the sampling process. |
ASSESSMENT CRITERION 3 |
No water other than the amount required for the sample is lost from the circuit. |
SPECIFIC OUTCOME 4 |
Explain and demonstrate the safety precautions to take and the personal protective equipment (PPE) to wear when handling biocides and other chemicals used in treating the water. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
The safe handling procedures of biocides and each of the other chemicals must conform to the requirements of the manufacturer of each product are listed and explained. |
ASSESSMENT CRITERION 2 |
Chemicals are handled using personal protective equipment and in accordance with the requirements of each manufacturer. |
SPECIFIC OUTCOME 5 |
Dose each circuit with the correct chemical(s) and in the amount prescribed in the analyst's report. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
Explain the need for accurate dosing. |
ASSESSMENT CRITERION 2 |
Chemicals are correctly identified. |
ASSESSMENT CRITERION 3 |
The prescribed amount of chemical is transferred from its container into a dosing cylinder without spillage. |
ASSESSMENT CRITERION 4 |
The chemical is successfully put into the correct water circuit |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
UNIT STANDARD DEVELOPMENTAL OUTCOME |
N/A |
UNIT STANDARD LINKAGES |
N/A |
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO IDENTIFYING |
Identify and solve problems
|
UNIT STANDARD CCFO ORGANISING |
Organise and manage myself and my activities
|
UNIT STANDARD CCFO COLLECTING |
Collect, analyse, organise and critically evaluate information
|
UNIT STANDARD CCFO SCIENCE |
Use science and technology effectively and critically
|
UNIT STANDARD CCFO DEMONSTRATING |
Demonstrate an understanding of the world as a set of related systems
|
UNIT STANDARD ASSESSOR CRITERIA |
N/A |
REREGISTRATION HISTORY |
As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. |
UNIT STANDARD NOTES |
This unit standard replaces unit standard 13378, which is "Operate water treatment systems used in air-conditioning and refrigeration installations, Level 3, 3 credits.
Supplementary information: Questions must be answered and work done within a reasonable time. |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Elective | 65489 | National Certificate: Air-Conditioning, Refrigeration and Ventilation | Level 3 | NQF Level 03 | Passed the End Date - Status was "Reregistered" |
2023-06-30 | MERSETA |
Elective | 48963 | National Certificate: Air-Conditioning, Refrigeration and Ventilation | Level 3 | NQF Level 03 | Passed the End Date - Status was "Reregistered" |
2009-03-12 | Was MERSETA until Last Date for Achievement |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
NONE |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |