All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |
SOUTH AFRICAN QUALIFICATIONS AUTHORITY |
REGISTERED UNIT STANDARD THAT HAS PASSED THE END DATE: |
Sterilise or pasteurise a liquid food product using direct steam injection technology |
SAQA US ID | UNIT STANDARD TITLE | |||
11615 | Sterilise or pasteurise a liquid food product using direct steam injection technology | |||
ORIGINATOR | ||||
SGB Food | ||||
PRIMARY OR DELEGATED QUALITY ASSURANCE FUNCTIONARY | ||||
- | ||||
FIELD | SUBFIELD | |||
Field 06 - Manufacturing, Engineering and Technology | Manufacturing and Assembly | |||
ABET BAND | UNIT STANDARD TYPE | PRE-2009 NQF LEVEL | NQF LEVEL | CREDITS |
Undefined | Regular | Level 3 | NQF Level 03 | 8 |
REGISTRATION STATUS | REGISTRATION START DATE | REGISTRATION END DATE | SAQA DECISION NUMBER | |
Passed the End Date - Status was "Reregistered" |
2018-07-01 | 2023-06-30 | SAQA 06120/18 | |
LAST DATE FOR ENROLMENT | LAST DATE FOR ACHIEVEMENT | |||
2024-06-30 | 2027-06-30 |
In all of the tables in this document, both the pre-2009 NQF Level and the NQF Level is shown. In the text (purpose statements, qualification rules, etc), any references to NQF Levels are to the pre-2009 levels unless specifically stated otherwise. |
This unit standard does not replace any other unit standard and is not replaced by any other unit standard. |
PURPOSE OF THE UNIT STANDARD |
A person credited with this unit standard is able to:
This unit standard is for anyone who works in a food or beverage manufacturing environment who is responsible for sterilising or pasteurising food or beverage products using direct steam injection technology. This unit standard will contribute to the full development of the learner within the food or beverage manufacturing environment by providing recognition, further mobility and transportability within the field of manufacturing and assembly. The skills, knowledge and understanding demonstrated within this unit standard are essential for social and economic transformation and will contribute to the upliftment and economic growth within the food or beverage manufacturing and processing environment. |
LEARNING ASSUMED TO BE IN PLACE AND RECOGNITION OF PRIOR LEARNING |
Description of required skills:
|
UNIT STANDARD RANGE |
The scope of this unit standard is for anyone who works in a food or beverage manufacturing environment who is responsible for sterilising or pasteurising food or beverage products using direct steam injection technology.
In the context of this unit standard a liquid food product is any free flowing or viscous food product, e.g. molasses or cream, and can also include beverage products. Direct steam injection refers to an automated process in which the food or beverage product comes into direct contact with the sterilising or pasteurising agent (steam). The level assigned to this unit standard is appropriate because the process requires a range of well-developed skills and offers a significant choice of procedures. Some relevant theoretical knowledge, interpretation of available information, discretion and judgement, as well as a range of known responses to familiar problems are employed. The application of this unit standard is to qualify the person for certification in skilled occupations and sub-trades. |
Specific Outcomes and Assessment Criteria: |
SPECIFIC OUTCOME 1 |
Demonstrate knowledge of direct steam sterilisation or pasteurisation of liquid food products. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. The purpose and principles of sterilisation or pasteurisation of a liquid food product is explained according to standard operating procedures and food principles. |
ASSESSMENT CRITERION 2 |
2. The terms "sterility" and "commercial sterility" are defined according to standard food principles and in terms of the effect thereof on micro-organisms and their spores. |
ASSESSMENT CRITERION 3 |
3. The logarithmic reduction of spores and micro-organisms in sterilised or pasteurised liquid food products is explained according to standard food and microbiological principles. |
ASSESSMENT CRITERION 4 |
4. The way in which efficiency of sterilisation or pasteurisation is established is explained according to standard operating procedures. |
ASSESSMENT CRITERION 5 |
5. The operating principles of the equipment used for direct steam sterilisation or pasteurisation of liquid food products are described according to standard operating procedures. |
ASSESSMENT CRITERION 6 |
6. The components of the equipment and system used for direct steam sterilisation or pasteurisation of liquid food products are identified and the purpose of each component is explained. |
ASSESSMENT CRITERION 7 |
7. The requirements for the steam used in direct steam sterilisation or pasteurisation processes are identified and the reasons for it are explained according to standard operating procedures and food principles. |
ASSESSMENT CRITERION 8 |
8. The cleaning and sanitising requirements of the equipment used in direct sterilisation or pasteurisation of liquid food products are explained in line with standard operating procedures, as well as standard food and manufacturer`s cleaning and sanitising principles. |
ASSESSMENT CRITERION RANGE |
The explanations covers:
|
ASSESSMENT CRITERION 9 |
9. Food safety practices and procedures for direct steam sterilisation or pasteurisation are identified and explained according to standard operating procedures. |
SPECIFIC OUTCOME 2 |
Prepare for direct steam sterilisation or pasteurisation of a liquid food product. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. Personal preparation is done according to standard operating procedures. |
ASSESSMENT CRITERION RANGE |
Personal preparation refers to practices that ensure hygiene, personal and product safety. |
ASSESSMENT CRITERION 2 |
2. The sterilisation or pasteurisation system is sanitised according to standard operating procedures. |
ASSESSMENT CRITERION 3 |
3. Sanitising materials are handled according to standard operating procedures and safety requirements. |
ASSESSMENT CRITERION 4 |
4. The relevant parameters are set according to standard operating procedures. |
ASSESSMENT CRITERION 5 |
5. The reasons for specific values of the different parameters are explained according to standard food principles, the manufacturer`s specifications and minimum legal specifications. |
ASSESSMENT CRITERION 6 |
6. The sterilisation or pasteurisation system is started up according to standard operating procedures. |
ASSESSMENT CRITERION 7 |
7. Common problems during start up are solved within scope of work. |
ASSESSMENT CRITERION RANGE |
Problem solving includes:
|
SPECIFIC OUTCOME 3 |
Sterilise or pasteurise a liquid food product using direct steam injection. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. A liquid food product is sterilised or pasteurised according to standard operating procedures. |
ASSESSMENT CRITERION 2 |
2. Equipment is handled according to standard operating procedures. |
ASSESSMENT CRITERION 3 |
3. Quality assurance parameters for direct steam sterilisation or pasteurisation are monitored and controlled according to standard operating procedures. |
ASSESSMENT CRITERION RANGE |
Parameters to be monitored and controlled may include, but are not limited to:
|
ASSESSMENT CRITERION 4 |
4. Samples are taken at required intervals in accordance with standard operating procedures. |
ASSESSMENT CRITERION 5 |
5. Samples are dispatched to designated areas for analysis. |
ASSESSMENT CRITERION 6 |
6. Results of sample analysis are interpreted and a conclusion is drawn on the efficiency of sterilisation or pasteurisation in terms of food safety requirements and site specifications. |
ASSESSMENT CRITERION RANGE |
Parameters to be monitored and controlled may include, but are not limited to:
|
ASSESSMENT CRITERION 7 |
7. Sterilised or pasteurised products are produced to conform to site-specifications. |
ASSESSMENT CRITERION 8 |
8. Records of the process are kept in accordance with standard operating procedures. |
ASSESSMENT CRITERION 9 |
9. Where a direct steam steriliser or pasteuriser is operated simultaneously with other production actions or processes, it is synchronized according to standard operating procedures. |
ASSESSMENT CRITERION 10 |
10. Common problems are solved within scope of work. |
ASSESSMENT CRITERION RANGE |
Problem solving includes:
|
SPECIFIC OUTCOME 4 |
Perform shut down procedures. |
ASSESSMENT CRITERIA |
ASSESSMENT CRITERION 1 |
1. The sterilising or pasteurising system is shut down according to standard operating procedures. |
ASSESSMENT CRITERION 2 |
2. Decisions to clean and sanitise the sterilising or pasteurising system, in conjunction with other equipment, are based on standard operating procedures. |
ASSESSMENT CRITERION RANGE |
Decisions refer to:
|
ASSESSMENT CRITERION 3 |
3. The sterilising or pasteurising system is cleaned and sanitised according to standard operating and safety procedures. |
ASSESSMENT CRITERION 4 |
4. Quality assurance parameters for cleaning and sanitising are monitored and controlled according to standard operating procedures. |
ASSESSMENT CRITERION RANGE |
Parameters to be monitored and controlled include:
|
ASSESSMENT CRITERION 5 |
5. Cleaning and sanitising materials are handled according to standard operating procedures. |
ASSESSMENT CRITERION 6 |
6. Cleaning equipment and materials are stored in designated areas according to work-site requirements. |
ASSESSMENT CRITERION 7 |
7. Waste from the cleaning process is handled and disposed of according to standard operating procedures and legal requirements. |
ASSESSMENT CRITERION 8 |
8. Records are kept according to standard operating procedures. |
ASSESSMENT CRITERION 9 |
9. All the symptoms and possible causes of all faults, or potential faults, that occur during the equipment shut down, cleaning and sanitising are identified and corrective actions are taken within scope of work. |
ASSESSMENT CRITERION 10 |
10. The equipment is left clean and ready for re-use. |
ASSESSMENT CRITERION 11 |
11. The work area is left in a safe and clean condition. |
UNIT STANDARD ACCREDITATION AND MODERATION OPTIONS |
UNIT STANDARD ESSENTIAL EMBEDDED KNOWLEDGE |
Embedded knowledge is reflected within the assessment criteria of each specific outcome. |
UNIT STANDARD DEVELOPMENTAL OUTCOME |
N/A |
UNIT STANDARD LINKAGES |
N/A |
Critical Cross-field Outcomes (CCFO): |
UNIT STANDARD CCFO IDENTIFYING |
Identify and solve problems in which response displays that responsible decisions, using critical and creative thinking, have been made by:
Evident in the following Specific Outcomes: |
UNIT STANDARD CCFO WORKING |
Work effectively with others as a member of a team, group, organisation or community by:
Evident in the following Specific Outcome: |
UNIT STANDARD CCFO ORGANISING |
Organise and manage oneself and one`s activities responsibly and effectively by:
Evident in the following Specific Outcomes: |
UNIT STANDARD CCFO COLLECTING |
Collect, analyse, organise and critically evaluate information by:
Evident in the following Specific Outcome: |
UNIT STANDARD CCFO COMMUNICATING |
Communicate effectively by using mathematical and/or language skills in the modes of oral and/or written presentations by:
Evident in the following Specific Outcomes: |
UNIT STANDARD CCFO SCIENCE |
Use science and technology effectively and critically, showing responsibility towards the environment and health of others by:
Evident in the following Specific Outcomes: |
UNIT STANDARD CCFO DEMONSTRATING |
Demonstrate an understanding of the world as a set of related systems by recognising that problem solving contexts do not exist in isolation by:
Evident in the following Specific Outcomes: |
UNIT STANDARD CCFO CONTRIBUTING |
Contribute to the full personal development of each learner and the social and economic development of the society at large.
Evident in all Specific Outcomes. |
UNIT STANDARD ASSESSOR CRITERIA |
N/A |
REREGISTRATION HISTORY |
As per the SAQA Board decision/s at that time, this unit standard was Reregistered in 2012; 2015. |
UNIT STANDARD NOTES |
Supplementary Information:
Legal requirements: The following acts and/or codes, current and future regulations and amendments will be applicable: Definition of terms within this unit standard: Terminology & clarification/explanation/definition: Commercial sterility: Refers to a situation in which all disease-causing and food or beverage spoiling micro-organisms are killed during sterilisation or pasteurisation but the spores of these micro-organisms are not necessarily killed. Liquid food product: Refers to any free flowing or viscous food product, e.g. molasses or cream, and can also include beverage products. Sterile/Sterility: A sterile product contains no living micro-organisms or spores. Sterilised products are manufactured by means of sterilisation through which the product is heated to such a high temperature that no living micro-organisms or their spores survive. Sterilisation or pasteurisation with direct steam injection: Refers to the processes by which a food or beverage product is heat treated to obtain commercial sterility. These processes are automated, in which the food or beverage product comes into direct contact with the sterilising or pasteurising agent (steam). Standard operating procedures: Refer to company procedures, prescribed procedures from the manufacturer, personal and food safety procedures, good manufacturing practices, best practices, applicable legislation, time frames, recipes and specifications. |
QUALIFICATIONS UTILISING THIS UNIT STANDARD: |
ID | QUALIFICATION TITLE | PRE-2009 NQF LEVEL | NQF LEVEL | STATUS | END DATE | PRIMARY OR DELEGATED QA FUNCTIONARY | |
Core | 22630 | National Certificate: Food and Beverage Manufacturing Technology: Yeast Manufacturing Technology | Level 3 | NQF Level 03 | Passed the End Date - Status was "Reregistered" |
2016-12-31 | FOODBEV |
PROVIDERS CURRENTLY ACCREDITED TO OFFER THIS UNIT STANDARD: |
This information shows the current accreditations (i.e. those not past their accreditation end dates), and is the most complete record available to SAQA as of today. Some Primary or Delegated Quality Assurance Functionaries have a lag in their recording systems for provider accreditation, in turn leading to a lag in notifying SAQA of all the providers that they have accredited to offer qualifications and unit standards, as well as any extensions to accreditation end dates. The relevant Primary or Delegated Quality Assurance Functionary should be notified if a record appears to be missing from here. |
NONE |
All qualifications and part qualifications registered on the National Qualifications Framework are public property. Thus the only payment that can be made for them is for service and reproduction. It is illegal to sell this material for profit. If the material is reproduced or quoted, the South African Qualifications Authority (SAQA) should be acknowledged as the source. |